Khandelwal Cables Limited

Home  |  Quality  |  Infrastructure  |  Award & Recognition  |  Contact us  |  Query  
Khandelwal Cables Ltd.Khandelwal Cables Ltd.

Khandelwal Cables Ltd.Khandelwal Cables Ltd.Khandelwal Cables Ltd.
Quality Assurence




Auto Cables


Bright annealed Electrolytic Copper Conductors - insulated with PVC Compound as per BS 6745, IS 5831 to withstand high Electrical and Mechanical stresses and resistant to oil, fuel, ozone etc. also. Braided and Lacquered to improve fire resistance properties.
Suitable for wiring of all kinds of vehicles - cars, jeeps, trucks, tractors, buses, railway-locomotives, trams, caravans etc. for battery-ignition, starter, lighting, steering column, wind screen wipers, horn, signalling, high tension and heavy duty circuits. Manufactured to standard specifications BS 6862, BS 1862, IS 2465 and to derive our specifications.

AS PER BS : 6862

Conductor
Size
Conductor
Area
Current
Rating
Overall Diameter ( Max )
PVC Insulated PVC Insulated Braided & Lacquered
( mm ) ( mm ²) ( Amps ) ( mm ) ( mm )
7/0.3 ( 2mm ) 0.5 4 2.1 3.1
9/0.3 ( 3mm ) 0.6 6 2.5 3.5
14/0.3 ( 4mm ) 1.0 11 2.7 3.7
28/0.3 ( 5mm ) 2.0 17 3.4 4.4
35/0.3 ( 6mm ) 2.5 19 3.8 4.8
44/0.3 ( 7mm ) 3.0 22 4.2 5.2
65/0.3 ( 8mm ) 4.5 28 5.1 6.1
120/0.3 ( 9mm ) 8.0 39 7.0 8.0
80/0.4 10 45 7.5 -
126/0.4 16 60 8.7 -
266/0.3 20 68 9.5 -
37/0.9 25 76 9.7 -
61/0.9 40 120 11.8 -
HIGH TENSION WIRES :
19/0.3 1.3 12 7.0 -

AS PER IS : 2465

Conductor
Size
Conductor
Area
Current
Rating
Overall Diameter ( Max )
PVC Insulated PVC Insulated Braided & Lacquered
( mm ) ( mm ²) ( Amps ) ( mm ) ( mm )
10/0.30 0.7 6 2.5 3.2
15/0.30 1.0 11 2.7 3.4
22/0.30 1.5 15 3.0 3.7
29/0.30 2.0 17 3.2 3.9
36/0.30 2.5 19 3.4 4.1
57/0.30 4.0 26 4.8 5.5
85/0.30 6.0 34 5.6 6.3
140/0.30 10.0 45 7.1 7.8
101/0.45 16.0 60 8.4 9.1
168/0.45 25.0 76 10.7 -
220/0.45 35.0 93 11.8 -
325/0.45 50.0 148 14.1 -
440/0.45 70.0 188 16.2 -
HIGH TENSION WIRES :
17/0.3 1.2 11 7.0 -

Current ratings are applicable for cables in enclosed areas and for an ambient temparature of 30° C. Other Conductor sizes in desired insulation thickness are manufactured as per customer needs. Supply of all cables for Panels Wiring is subject to provisions of Copper Control Order.
Colour : Standard colours of insulation Black, Red, Blue, Grey, Yellow, White, Brown, Orange, Pink and Violet..
Packing : In 91.4 mtrs ( 100 yds ) / 100 mtrs. coils.


Home  |  Quality  |  Infrastructure  |  Award & Recognition  |  Consultancy  |  Contact us  |  Query
Khandelwal Cables Ltd. ® 2009 - 2010